All guides

Acoustics · 5 min read

Office acoustics: the basics

RT60, absorption, insulation. How do the key parameters differ, and which of them really affects comfort at work?

Two different acoustic problems

In an office we can face two separate acoustic problems that need completely different solutions. The first is a reverberation time that is too long: sound bounces off hard surfaces and does not die away, so the space sounds like a sports hall. The second is sound passing between rooms or zones: a phone call heard across the whole floor, a meeting in the conference room audible through the wall.

Confusing these two problems is one of the most common mistakes when planning an office.

RT60: reverberation time

RT60 is the time it takes for the sound level to drop by 60 dB after the sound source stops. In practice it is measured with an app or a dedicated device: a short impulse is generated and the decay is recorded. For open-plan offices, the Polish standard PN-B-02151 recommends an RT60 of 0.4–0.6 s. In conference rooms the target is 0.3–0.5 s. A typical unfurnished office with hard floors and ceilings has an RT60 of 0.9–1.4 s.

Upholstered partitions, carpets, acoustic ceilings and upholstered furniture reduce RT60 by absorbing the energy of the sound wave.

Sound absorption

Absorption is measured with the absorption coefficient α (alpha) on a scale of 0–1. A material with α = 1 absorbs 100% of the energy of the incident sound. Upholstery fabrics used in office partitions achieve α ≈ 0.6–0.85 in the speech bands (500–2000 Hz). Glass has α ≈ 0.03–0.05, so it absorbs almost nothing.

  • High-density fabric: α ≈ 0.80–0.85 for 52 mm panels
  • Toughened glass: α ≈ 0.03
  • Acoustic glass with a PVB interlayer: α ≈ 0.06–0.10
  • Perforated sheet metal with an acoustic insert: α ≈ 0.50–0.70

Sound insulation in dB

Insulation (marked Rw or DnTw) measures by how many decibels a partition reduces the sound passing from one room to another. What matters most here is the mass and airtightness of the construction: seals, infill, profile thickness.

System 32 with upholstered infill achieves Rw ≈ 38–42 dB. With laminated glass the values are similar. That is comparable to a plasterboard stud wall.

System 20 and desk dividers are not designed for insulation: their job is absorption and visually marking out a zone.

Which solution to choose?

If the problem is general noise and a long reverberation time in an open space: absorption (fabric, acoustic ceilings, carpets). If the problem is conversations carrying between zones or rooms: insulation (System 32, a full-height partition to the ceiling, seals). If both: start with absorption, which is cheaper and more flexible, and use insulation selectively.

More articles