Installation · 5 min read
Installing partitions without a permit
Which systems need no notification, what conditions they must meet and what the handover report for the premises looks like after installation.
Building law and internal partitions
Under the Polish Building Law (Article 29 of the Act of 7 July 1994, as amended), building work that needs neither a building permit nor a notification includes "renovations and alterations that do not transfer loads onto load-bearing elements". Office partitions that do not transfer loads onto the ceiling or load-bearing walls do not, as a rule, need a notification. The key, however, is the distinction between system partitions and masonry or plasterboard walls. The latter may need a notification or even a permit if they change the functional layout of the premises or affect the building services.
Systems exempt from formalities
Desk dividers (Seal, Soft and similar), mounted only on the desk top with clamps, need no formalities. They do not touch the floor or the ceiling. Systems standing on adjustable feet (Soft, System 20, System 32), which rest on their own feet and are not fixed to the ceiling or load-bearing walls, are exempt from formalities. Conditions: the system does not transfer loads onto the ceiling, does not block escape routes and does not affect building services. If System 20 or 32 were to be anchored to the floor or walls, it may technically need notifying to the property manager or building owner (lease agreements often contain such requirements), but building law does not require a separate notification for non-load-bearing partitions.
Escape routes and fire regulations
Regardless of building formalities, every change to the office layout must comply with fire regulations:
- The minimum width of an escape route is 1.2 m for up to 20 people and 1.4 m for 21–300 people.
- Partitions must not restrict access to fire extinguishers, hydrants, electrical boxes or emergency exits.
- If the change of layout requires a change to the fire protection design, an opinion from a fire safety expert is needed.
The handover report for the premises
If the office is rented, the lease usually requires the original condition to be restored at the end of the lease. Systems on feet can be fully dismantled and moved without leaving a trace. Anchored systems may leave holes in the floor or walls that need filling. Before installation, it is worth photographing the current condition of the floor and ceiling. After installing freestanding systems, the law requires no handover documentation. For anchored systems, it is worth getting the building manager's written approval, which protects both sides.
A practical tip
For offices in rented space, the best choice is System 20 on adjustable feet or desk dividers. Zero formalities, zero traces, full freedom to reconfigure and move to a new office. System 32 is a heavier solution and works where the partition may be pushed (by wind or people). We often use it to create office spaces in halls and warehouses.